DUMMY DATA. TEST PAGE.
State STP MonitoringSewage Treatment Plant Monitoring System
Accessibility

Accessibility options

Adjust this page to your preferences.

Use Tab to navigate and Escape to close. Your device’s reduced-motion preference is also respected.

Effluent Diagnostics & Standards· CPCB Compliance

Water Quality Trends & Analysis

Review biological treatment progression, organic reduction efficiency, and regulatory compliance across all process stages.

BOD Removal Rate

94%

CPCB Target: ≤ 30 mg/L

COD Removal Rate

82%

CPCB Target: ≤ 250 mg/L

TSS Clarification

70%

CPCB Target: ≤ 100 mg/L

pH Neutral Band

6.5 – 8.5

Non-toxic discharge band

Biological Reduction Curve

Latest Complete Flow Set (INLET → MBBR1 → MBBR2 → OUTLET)

Multi-parameter laboratory analysis tracking organic degradation across biological carriers.

Sample Set: 11/16/2025, 5:48:37 PM

Last filtration

Collected: 11/16/2025, 5:48:37 PM
View last filtration data table
Last filtration. BOD, COD and TSS in mg/L; pH is dimensionless. Unavailable measurements are marked as not reported.
Sampling pointBOD (mg/L)COD (mg/L)TSS (mg/L)pH
INLET164.5250.1100.697.38
MBBR178.69180.4885.127.47
MBBR230.8198.7786.047.37
OUTLET10.3445.3230.267.13

Sampling Point Historical Trends

Time-series laboratory observations across individual treatment stages. Units: BOD, COD, and TSS in mg/L; pH is dimensionless.

Loading water quality trends.
Central Pollution Control Board Standards

Regulatory Discharge Norms vs. Raw Influent

EPA Schedule VI
ParameterTypical Raw InfluentCPCB Discharge LimitMinimum ReductionEnvironmental Impact
pH6.0 – 8.56.5 – 8.5Buffering / NeutralPrevents river acidification or heavy metals leaching
BOD (Biochemical Oxygen Demand)150 – 350 mg/L≤ 30 mg/L> 85% removalProtects dissolved oxygen in receiving waterbodies
COD (Chemical Oxygen Demand)300 – 700 mg/L≤ 250 mg/L> 75% removalEliminates recalcitrant and toxic organic pollutants
TSS (Total Suspended Solids)200 – 450 mg/L≤ 100 mg/L> 80% removalPrevents turbidity, sludge banks, and sunlight blockage

Parameter Diagnostic Reference

Scientific explanation of laboratory test markers and their biological significance.

pH (6.5 – 8.5)

Indicates acidity or alkalinity. Treated effluent must stay within this neutral band to prevent harm to aquatic life.

BOD (≤ 30 mg/L)

Biochemical Oxygen Demand measures biodegradable organic pollution. Lower values prevent oxygen depletion in rivers.

COD (≤ 250 mg/L)

Chemical Oxygen Demand captures total oxidizable organics and inorganics. High values signal toxic or non-biodegradable loads.

TSS (≤ 100 mg/L)

Total Suspended Solids measures fine particulates. Clarification and filtration ensure clear treated effluent.

MBBR Treatment Flow Architecture

Moving Bed Biofilm Reactor (MBBR) combines high-surface-area suspended carriers with aeration and secondary clarification.